Abstract

Groundwater flow significantly influences the evolution of the subsurface temperature field and the heat exchange performance of shallow ground-source heat pump systems. Moreover, the coupled hydraulic-thermal interactions between the above-ground pipe network and the underground borehole array substantially affect the load distribution behavior of borehole heat exchanger (BHE) arrays. To systematically investigate thermal interference and load-shifting phenomena within BHE arrays affected by groundwater flow, this study developed a coupled model based on the open-source software OpenGeoSys (OGS) and the thermodynamic toolkit TESPy. The proposed model simultaneously considers underground seepage characteristics, heat transfer within the borehole array, and the hydraulic and thermal balances of the ground pipe network. Compared with the decoupled model, incorporating pipe network coupling into the 25-BHE array simulation revealed that the decoupled model underestimates the heating load of the edge BHE by 26% and overestimates the outlet temperature of the central BHE by 1.9 K at the end of the 15th cooling season. Further simulations under different seepage scenarios demonstrate that as the Darcy velocity increased from 0 to 1×10−6 m/s, the load-shifting behavior in the BHE array first decreased and then increased. At a Darcy velocity of 1×10−6 m/s, asymmetric load redistribution intensified, causing the most upstream BHE to bear a 41.4% excess thermal load. Nevertheless, increasing the inter-borehole spacing from 3 m to 6 m under high Darcy velocity (1×10−6 m/s) reduced the peak shifted load by 63%, stabilized seasonal soil temperature fluctuations within 9 K, and kept the long-term cumulative soil temperature rise below 2 K at the end of the 15th year, while improving load distribution uniformity. These findings emphasize the need to account for load-shifting behavior in practical BHE projects influenced by groundwater flow and provide guidance for project design.
OriginalspracheEnglisch
Aufsatznummer129356
Seitenumfang19
FachzeitschriftInternational journal of heat and mass transfer
Jahrgang2026
AusgabenummerVol 271, Part 2
DOIs
PublikationsstatusVeröffentlicht - 15 Dez. 2026

Bibliographische Notiz

Publisher Copyright:
© 2026 Elsevier Ltd.

UN SDGs

Dieser Output leistet einen Beitrag zu folgendem(n) Ziel(en) für nachhaltige Entwicklung

  1. SDG 7 – Erschwingliche und saubere Energie
    SDG 7 – Erschwingliche und saubere Energie

Dieses zitieren