T1 - The role of zinc in the biocorrosion behavior of resorbable Mg‒Zn‒Ca alloys
AU - Cihova, Martina
AU - Martinelli, Elisabeth
AU - Schmutz, Patrik
AU - Myrissa, Anastasia
AU - Schäublin, Robin E.
AU - Weinberg, Annelie M.
AU - Uggowitzer, Peter J.
AU - Löffler, Jörg F.
PY - 2019/9/17
Y1 - 2019/9/17
N2 - Zinc- and calcium-containing magnesium alloys, denominated ZX alloys, excel as temporary implant materials because of their composition made of physiologically essential minerals and lack of commonly used rare-earth alloying elements. This study documents the specific role of nanometric intermetallic particles (IMPs) on the in vitro and in vivo biocorrosion behavior of two ZX-lean alloys, Mg‒Zn1.0‒Ca0.3 (ZX10) and Mg‒Zn1.5‒Ca0.25 (ZX20) (in wt.%). These alloys were designed according to thermodynamic considerations by finely adjusting the nominal Zn content towards microstructures that differ solely in the type of phase composing the IMPs: ZX10, with 1.0 wt.% Zn, hosts binary Mg2Ca-phase IMPs, while ZX20, with 1.5 wt.% Zn, hosts ternary IM1-phase IMPs. Electrochemical methods and the hydrogen-gas evolution method were deployed and complemented by transmission electron microscopy analyses. These techniques used in concert reveal that the Mg2Ca-type IMPs anodically dissolve preferentially and completely, while the IM1-type IMPs act as nano-cathodes, facilitating a faster dissolution of ZX20 compared to ZX10. Additionally, a dynamically increasing cathodic reactivity with progressing dissolution was observed for both alloys. This effect is explained by redeposits of Zn on the corroding surface, which act as additional nano-cathodes and facilitate enhanced cathodic reaction kinetics. The higher degradation rate of ZX20 was verified in vivo via micro-computed tomography upon implantation of both materials into femurs of Sprague DawleyⓇ rats. Both alloys were well integrated with direct bone‒implant contact observable 4 weeks post operationem, and an appropriately slow and homogeneous degradation could be observed with no adverse effects on the surrounding tissue. The results suggest that both alloys qualify as new temporary implant materials, and that a minor adjustment of the Zn content may function as a lever for tuning the degradation rate towards desired applications.
AB - Zinc- and calcium-containing magnesium alloys, denominated ZX alloys, excel as temporary implant materials because of their composition made of physiologically essential minerals and lack of commonly used rare-earth alloying elements. This study documents the specific role of nanometric intermetallic particles (IMPs) on the in vitro and in vivo biocorrosion behavior of two ZX-lean alloys, Mg‒Zn1.0‒Ca0.3 (ZX10) and Mg‒Zn1.5‒Ca0.25 (ZX20) (in wt.%). These alloys were designed according to thermodynamic considerations by finely adjusting the nominal Zn content towards microstructures that differ solely in the type of phase composing the IMPs: ZX10, with 1.0 wt.% Zn, hosts binary Mg2Ca-phase IMPs, while ZX20, with 1.5 wt.% Zn, hosts ternary IM1-phase IMPs. Electrochemical methods and the hydrogen-gas evolution method were deployed and complemented by transmission electron microscopy analyses. These techniques used in concert reveal that the Mg2Ca-type IMPs anodically dissolve preferentially and completely, while the IM1-type IMPs act as nano-cathodes, facilitating a faster dissolution of ZX20 compared to ZX10. Additionally, a dynamically increasing cathodic reactivity with progressing dissolution was observed for both alloys. This effect is explained by redeposits of Zn on the corroding surface, which act as additional nano-cathodes and facilitate enhanced cathodic reaction kinetics. The higher degradation rate of ZX20 was verified in vivo via micro-computed tomography upon implantation of both materials into femurs of Sprague DawleyⓇ rats. Both alloys were well integrated with direct bone‒implant contact observable 4 weeks post operationem, and an appropriately slow and homogeneous degradation could be observed with no adverse effects on the surrounding tissue. The results suggest that both alloys qualify as new temporary implant materials, and that a minor adjustment of the Zn content may function as a lever for tuning the degradation rate towards desired applications.
KW - Biocorrosion
KW - Electrochemistry
KW - Magnesium alloy
KW - Microstructure
KW - Nano-galvanic coupling
KW - Redeposition
KW - Transmission electron microscopy
UR - https://www.scopus.com/pages/publications/85074486206
U2 - 10.1016/j.actbio.2019.09.021
DO - 10.1016/j.actbio.2019.09.021
M3 - Article
C2 - 31539653
AN - SCOPUS:85074486206
SN - 1742-7061
VL - 100.2019
SP - 398
EP - 414
JO - Acta biomaterialia
JF - Acta biomaterialia
IS - December
ER -