TY - JOUR
T1 - Ammonium recovery from model solutions and sludge liquor with a combined ion exchange and air stripping process
AU - Eisbacher-Lubensky, Jan
AU - Ellersdorfer, Markus
AU - Stocker, Kristina
N1 - Publisher Copyright: © 2019 Elsevier Ltd
PY - 2019/12
Y1 - 2019/12
N2 - The recovery of ammonium (NH
4
+) from model (NH
4)
2SO
4 solutions as well as from sludge liquor of a communal waste water treatment plant was studied on the laboratory scale using the ion exchanger loop stripping process (ILS). The ILS process combines ion exchange and air stripping in a hybrid process and works with fixed bed columns containing natural zeolite (mainly clinoptilolite), which is alternately loaded and regenerated. The sodium hydroxide (NaOH) regeneration fluid is simultaneously air stripped. Ammonium is recovered in a subsequent acid scrubber as concentrated ammonium sulfate solution, which is a suitable reducing agent for industrial NOx recovery. Lab scale experiments with four loading and regeneration cycles demonstrate the technical feasibility of the process. The ammonium equilibrium increased after the first loading and regeneration cycles and ammonium uptake reached concentrations of 3 to 4 mg NH
4
+ L
−1 over four consecutive cycles. NaOH regeneration at pH values >11.5 recovered nearly the total amount of previously adsorbed ammonium. The stripped amount of NH
4
+ increased over the investigated cycles and in the final regeneration sequence approximately the whole amount of desorbed ammonium was simultaneously stripped. Ammonium exchange and recovery characteristics did not significantly change when real sludge liquor samples were used.
AB - The recovery of ammonium (NH
4
+) from model (NH
4)
2SO
4 solutions as well as from sludge liquor of a communal waste water treatment plant was studied on the laboratory scale using the ion exchanger loop stripping process (ILS). The ILS process combines ion exchange and air stripping in a hybrid process and works with fixed bed columns containing natural zeolite (mainly clinoptilolite), which is alternately loaded and regenerated. The sodium hydroxide (NaOH) regeneration fluid is simultaneously air stripped. Ammonium is recovered in a subsequent acid scrubber as concentrated ammonium sulfate solution, which is a suitable reducing agent for industrial NOx recovery. Lab scale experiments with four loading and regeneration cycles demonstrate the technical feasibility of the process. The ammonium equilibrium increased after the first loading and regeneration cycles and ammonium uptake reached concentrations of 3 to 4 mg NH
4
+ L
−1 over four consecutive cycles. NaOH regeneration at pH values >11.5 recovered nearly the total amount of previously adsorbed ammonium. The stripped amount of NH
4
+ increased over the investigated cycles and in the final regeneration sequence approximately the whole amount of desorbed ammonium was simultaneously stripped. Ammonium exchange and recovery characteristics did not significantly change when real sludge liquor samples were used.
UR - http://www.scopus.com/inward/record.url?scp=85070221308&partnerID=8YFLogxK
U2 - 10.1016/j.jwpe.2019.100909
DO - 10.1016/j.jwpe.2019.100909
M3 - Article
SN - 2214-7144
VL - 32.2019
JO - Journal of Water Process Engineering
JF - Journal of Water Process Engineering
IS - December
M1 - 100909
ER -