T1 - Determination of rare earth elements, U and Th in environmental samples by Inductively coupled plasma double focussing sectorfield mass spectrometry
AU - Prohaska, Thomas
AU - Hann, Stephan
AU - Latkoczy, Christopher
AU - Stingeder, Gerhard
PY - 1999
Y1 - 1999
N2 - The excellent capability of high resolution inductively coupled plasma sectorfield mass spectrometry for measurements of the rare earth elements Th and U is demonstrated by investigating different materials such as geological matrices (sediments, soils), plant tissues and marine animal tissues. Appropriate digestion of the samples resulted in complex matrices, especially in the case of silicate containing samples. The elemental loss in silicate residues of plant material was found to be up to 30% and therefore required HF-containing digestion methods. The high concentration of matrix elements leads to spectral interferences, which are investigated by measuring the elements with different mass resolution. High mass resolution is shown to be a prerequisite for accurate determination of Sc and Y, respectively. Furthermore, effects of non spectral interferences are investigated and could be properly corrected for by using 115 In as internal standard. Moreover, the capability of a microconcentric nebulizer in combination with a membrane desolvation unit compared to a conventional microconcentric nebulizer is discussed with respect to suppression of spectral interferences. Oxide interferences could be reduced to a negligible amount, whereas it could be observed that high salt freight leads to a blockage of the membrane.
AB - The excellent capability of high resolution inductively coupled plasma sectorfield mass spectrometry for measurements of the rare earth elements Th and U is demonstrated by investigating different materials such as geological matrices (sediments, soils), plant tissues and marine animal tissues. Appropriate digestion of the samples resulted in complex matrices, especially in the case of silicate containing samples. The elemental loss in silicate residues of plant material was found to be up to 30% and therefore required HF-containing digestion methods. The high concentration of matrix elements leads to spectral interferences, which are investigated by measuring the elements with different mass resolution. High mass resolution is shown to be a prerequisite for accurate determination of Sc and Y, respectively. Furthermore, effects of non spectral interferences are investigated and could be properly corrected for by using 115 In as internal standard. Moreover, the capability of a microconcentric nebulizer in combination with a membrane desolvation unit compared to a conventional microconcentric nebulizer is discussed with respect to suppression of spectral interferences. Oxide interferences could be reduced to a negligible amount, whereas it could be observed that high salt freight leads to a blockage of the membrane.
U2 - 10.1039/A806720A
DO - 10.1039/A806720A
M3 - Article
SN - 0267-9477
VL - 14.1999
SP - 1
EP - 8
JO - Journal of analytical atomic spectrometry
JF - Journal of analytical atomic spectrometry
IS - 1
ER -