Skip to main navigation Skip to search Skip to main content

Downscaling metal-dielectric interface fracture experiments to sub-micron dimensions: A feasibility study using TEM

  • Bernhard Völker
  • , Walther Heinz
  • , Roman Roth
  • , Jörg Martin Batke
  • , Megan Cordill
  • , Gerhard Dehm
  • KAI - Kompetenzzentrum Automobil- und Industrieelektronik GmbH
  • Infineon Technologies AG Austria
  • Erich Schmid Institute of Materials Science
  • Max-Planck-Institut für Eisenforschung GmbH

Research output: Contribution to journal › Article › Research › peer-review

7 Citations (Scopus)

Abstract

In this study a bending beam approach is miniaturized to the sub-micrometer size regime for in-situ transmission electron microscopy (TEM) investigations. The purpose of this study was to evaluate the feasibility of this method for determining interface fracture energies for metal-dielectric systems, which are comparable to other methods. The interfaces under investigation are Cu/borophosphosilicate glass (BPSG) and W(20. at.% Ti)/BPSG as examples for a weak and a strong interface, respectively. It was possible to fracture the Cu/BPSG interface during in-situ TEM experiments and to obtain estimates for the interface fracture energy comparable to literature values. However, the TEM approach imposes challenges which can complicate the determination of an interface energy release rate; these influences are discussed. The miniaturized TEM approach failed for W(20. at.% Ti)/BPSG because no interface fracture occurred in this case. Thus it is concluded, that the experimental setup of the in-situ TEM bending beam method utilized in this study is useful for weak interfaces but for strongly adhering interfaces it is inappropriate.
Original languageEnglish
Pages (from-to)1-7
Number of pages7
JournalSurface & coatings technology
Volume270.2015
Issue number25 May
DOIs
Publication statusPublished - 25 Mar 2015

Keywords

  • Bending beam
  • In-situ TEM
  • Interface fracture
  • Submicron-sized samples

Cite this