Skip to main navigation Skip to search Skip to main content

Mitigating load-shifting behavior in shallow geothermal borehole arrays: Advection-driven thermal interference analysis

  • Siyu Guo
  • , Wanlong Cai
  • , Fenghao Wang
  • , Shuang Chen
  • , Boyan Meng
  • , Jun Liu
  • , Yuping Zhang
  • , Chaofan Chen
  • School of Human Settlements and Civil Engineering, Xi'an Jiaotong University
  • Henan University of Science and Technology
  • Branch Office Berlin
  • Three Gorges Geotechnical Consultants Co.
  • Ministry of Natural Resources of the People's Republic of China

Research output: Contribution to journal › Article › Research › peer-review

Abstract

Groundwater flow significantly influences the evolution of the subsurface temperature field and the heat exchange performance of shallow ground-source heat pump systems. Moreover, the coupled hydraulic-thermal interactions between the above-ground pipe network and the underground borehole array substantially affect the load distribution behavior of borehole heat exchanger (BHE) arrays. To systematically investigate thermal interference and load-shifting phenomena within BHE arrays affected by groundwater flow, this study developed a coupled model based on the open-source software OpenGeoSys (OGS) and the thermodynamic toolkit TESPy. The proposed model simultaneously considers underground seepage characteristics, heat transfer within the borehole array, and the hydraulic and thermal balances of the ground pipe network. Compared with the decoupled model, incorporating pipe network coupling into the 25-BHE array simulation revealed that the decoupled model underestimates the heating load of the edge BHE by 26% and overestimates the outlet temperature of the central BHE by 1.9 K at the end of the 15th cooling season. Further simulations under different seepage scenarios demonstrate that as the Darcy velocity increased from 0 to 1×10−6 m/s, the load-shifting behavior in the BHE array first decreased and then increased. At a Darcy velocity of 1×10−6 m/s, asymmetric load redistribution intensified, causing the most upstream BHE to bear a 41.4% excess thermal load. Nevertheless, increasing the inter-borehole spacing from 3 m to 6 m under high Darcy velocity (1×10−6 m/s) reduced the peak shifted load by 63%, stabilized seasonal soil temperature fluctuations within 9 K, and kept the long-term cumulative soil temperature rise below 2 K at the end of the 15th year, while improving load distribution uniformity. These findings emphasize the need to account for load-shifting behavior in practical BHE projects influenced by groundwater flow and provide guidance for project design.
Original languageEnglish
Article number129356
Number of pages19
JournalInternational journal of heat and mass transfer
Volume2026
Issue numberVol 271, Part 2
DOIs
Publication statusPublished - 15 Dec 2026

Bibliographical note

Publisher Copyright: © 2026 Elsevier Ltd.

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 7 - Affordable and Clean Energy
    SDG 7 Affordable and Clean Energy

Keywords

  • Borehole heat exchanger array
  • Darcy velocity
  • Inter-borehole spacing
  • Load-shifting
  • OpenGeoSys

Cite this